SESIP evaluates IoT platforms — MCUs, secure enclaves, RTOS/OS layers, connectivity stacks — against a catalogue of reusable security functional requirements (« verification of platform identity », « secure update », « protection of data at rest ») at five assurance levels. The methodology descends from Common Criteria and keeps its discipline, but replaces open-ended evaluation with a scoped, platform-appropriate exercise that labs can price and schedule like engineering.
The design goal is composition. A device maker building on a SESIP-certified platform doesn’t re-prove the platform’s claims; their evaluation consumes the certificate and covers only what they added. That is how one chip vendor’s investment propagates through module makers to device brands — and why SESIP claims are written as discrete, machine-readable-ish statements rather than monolithic targets. CEN/CENELEC adoption as EN 17927 gave the methodology a European legal identity that schemes and regulations can reference; PSA Certified applies the same logic with an Arm-flavoured requirement profile and its own branding tiers.
In the CRA era the composition mechanism becomes commercially decisive: with thousands of device makers needing conformity evidence by December 2027, « built on a certified platform » is the shortest credible sentence in any technical file — provided the platform certificate’s claims and composition rationale were written to be consumed, not just displayed.